<img alt="" src="https://www.acuteinspiration-inventive.com/805139.png" style="display:none;">

Anti-ligature Ventilation Plenum

Safe, hygienic air distribution for secure mental health environments designed and built with the practical demands of NHS specification in mind.

Anti-ligature Ventilation Plenum draws on Contour Heating’s years of working within mental health. It is designed specifically for these environments: connecting standard circular ductwork to IP3X-rated anti-ligature grilles, with a construction specification that addresses safety, hygiene, and long-term maintainability from the outset.

Download Product Information
Plenum_front2
Plenum_corner left 1
C1M01130
Plenum_back close
Plenum_corner left 2
Plenum_front2
Plenum_corner left 1
C1M01130
Plenum_back close
Plenum_corner left 2

Designed for HBN 03-01 Environments

 Getting ventilation right in a secure mental health ward is more complex than it looks. Every element of the built environment comes under scrutiny — from CQC inspections to clinical sign-off and infection prevention review. The Anti-ligature Ventilation Plenum from Contour Heating is designed specifically for these environments: connecting standard circular ductwork to IP3X-rated anti-ligature grilles, with a construction specification that addresses safety, hygiene, and long-term maintainability from the outset. 

 

Plenum_mid shot

Ward Uses

The Anti-ligature Ventilation Plenum is specified for secure mental health estates where standard ventilation grilles present unacceptable risk. Typical applications include:

Acute adult inpatient wards requiring anti-ligature specification

PICU and high-dependency mental health settings

CAMHS inpatient units

Rehabilitation and step-down wards

Seclusion, low-stimulus, and en-suite bathroom areas

Any space where standard ventilation grilles present a ligature or anti-tamper risk

The plenum is suitable for both new-build hospital construction and phased refurbishment programmes in occupied clinical environments.

Plenum_mide right

Key features

Each element of the Anti-ligature Ventilation Plenum specification is deliberate. The product is built for environments where reliability, safety, and maintainability are not negotiable.

IP3X-rated anti-ligature punched grille; 2mm holes at 4mm centres.
1.5mm Zintec steel (full frame); Magnelis steel available for wet areas.
BioCote® antimicrobial agent as standard.
Pin Torx button head anti-ligature fixings; threaded inserts for maintenance access; all fixings internal.
Top-entry circular spigot; 125mm, 160mm, 200mm nominal sizes; compatible with standard round flexible and rigid ductwork.
Typically 8–10 Pa at nominal flow rates; extract higher — factor into system design.

Technical specification

The following table summarises the core specification of the Anti-ligature Ventilation Plenum:

Grille size H × W × D  Spigot
200 × 200 mm 250 × 250 × 250 mm Ø125 mm
300 × 300 mm 350 × 350 × 300 mm Ø160 mm
450 × 450 mm 520 × 520 × 400 mm Ø200 mm

 

 

Plenum_mid shot

Technical Data

IP3X anti-ligature grille

 The punched steel grille uses 2mm holes at 4mm centres in a triangular pitch. This restricts the passage of objects, reduces ligature opportunities, and maintains the airflow performance the system needs. It sits flush with the ceiling once installed, with no projecting edges. 

1.5mm Zintec steel

 The plenum body is formed from 1.5mm Zintec steel — a specification suited to high-use clinical settings where impact and wear are everyday considerations. Magnelis steel is available for wet-room and en-suite environments where additional corrosion resistance is needed. 

Low pressure drop

 Supply air testing shows a pressure drop typically in the range of 8–10 Pa at nominal flow rates — low enough to avoid adverse system effects. Extract pressure drop is higher due to grille restriction and should be factored into system design at specification stage. 

BioCote® antimicrobial protection

 Powder coated inside and out as standard on RAL 9003 white models. BioCote® antimicrobial agent is incorporated into the finish, supporting hygiene standards and infection prevention requirements in clinical environments. 

Anti-ligature fixings

 Pin Torx button head fixings create a flush, secure closure. All fixing points are located internally, protecting against unauthorised access, removal, or manipulation. Threaded inserts support repeated removal and refitting for maintenance without wear to the fixing points. 

Flush ceiling installation

 The grille sits flush with the ceiling surface once installed, with the plenum body attached internally to the ductwork. There are no projecting frames, exposed fixings, or surface-mounted elements that could present a risk or accumulate contamination. 

Supply and extract

 The plenum supports both supply and extract applications. For supply, air enters via the top-entry spigot, diffuses through the plenum chamber, and passes through the grille into the room. For extract, the airflow direction is reversed. This allows a consistent product specification across ventilation systems. 

Richard_Holland_Photo

Richard Holland National Sales Manager

Need Some Advice From One of Our Experts?

We're here to help. For more information, or to find out more about our services, including site surveys; or talk to us about our comprehensive product range, please contact us today. We’ll do our best to get back to you within one working day.

Robert_Bennett_Photo

Robert Bennett Project Surveyor

Need Some Advice From One of Our Experts?

We're here to help. For more information, or to find out more about our services, including site surveys; or talk to us about our comprehensive product range, please contact us today. We’ll do our best to get back to you within one working day.

Laura_Oliver_Photo

Laura Oliver Customer Service Manager

Need Some Advice From One of Our Experts?

We're here to help. For more information, or to find out more about our services, including site surveys; or talk to us about our comprehensive product range, please contact us today. We’ll do our best to get back to you within one working day.

Ready to take the next step?

Just fill out the form in as much detail as you can, and an expert will be in touch within 24 hours.