<img alt="" src="https://www.acuteinspiration-inventive.com/805139.png" style="display:none;">

TRV Valve Kits for LST Radiators

Contour’s Danfoss TRV valve kits bring together thermostatic controls, valve bodies and lockshields to suit a range of radiator installations. With external temperature adjustment, remote sensing and built-in sensor options, you can choose an arrangement that suits how the room temperature is measured and who needs access to the controls. Each arrangement is available with a conventional RA-N valve or an RA-DV Dynamic Valve™, which adds built-in pressure regulation and preset flow control to simplify system balancing. Our technical team can help you select the appropriate kit for your radiator, casing and project requirements.

Choosing your kit in three steps 

  • Decide who controls the temperature, and from where. External adjuster (staff or occupant, outside the cover), remote sensor (head inside, sensor inside or outside) or internal sensor and control (everything inside the cover).
  •  
  • Choose your balancing method. RA-N with a lockshield for preset balancing; RA-DV Dynamic Valve™ for pressure-independent flow limitation set at the valve.
  •  
  • Confirm connections and access with our technical team so the kit, radiator and cover arrive as one specification — no retrofit surprises on site.

  •  
  •  

 External TRV Kits

Ideal for wards, classrooms and communal areas where users or staff need to adjust the temperature without opening the radiator cover. An externally mounted remote adjuster controls the valve inside via a capillary connection, providing accessible temperature adjustment while keeping the valve, pipework and lockshield enclosed within the LST cover.


  •  
Kit 1 - Full 4

Kit 1

Remote Adjuster TRV Kit with RA-N Valve

Combines a Danfoss RA 5062 remote temperature adjuster with an RA-N DN15 angled valve body and RLV-S DN15 angled lockshield. The adjuster provides room temperature sensing and adjustment outside the LST cover, with an 8–28°C setting range, frost protection, and options to limit or lock the temperature setting.

Suitable for two-pipe heating systems, the RA-N valve incorporates adjustable presetting to support hydraulic balancing.

 

 

Kit 2

Remote Adjuster TRV Kit with RA-DV Dynamic Valve™

Combines a Danfoss RA 5062 remote temperature adjuster with an RA-DV DN15 angled Dynamic Valve™ and RLV-S DN15 angled lockshield. The adjuster provides room temperature sensing and adjustment outside the LST cover, with an 8–28°C setting range, frost protection, and options to limit or lock the temperature setting.

Designed for two-pipe heating systems, the RA-DV combines thermostatic control with built-in differential pressure regulation and automatic hydraulic balancing. Maximum flow can be set between 10–135 litres per hour, with the regulator maintaining the selected flow limit as system pressure changes within its operating range.

  •  

     

Kit 2 - Full 2

 Remote Sensor TRV Kits


For installations where the thermostatic head is enclosed within the LST cover and regular temperature adjustment is not required. A separate sensor is mounted outside the cover or, at low level within the cover to accurately measure room temperature rather than the warmer air inside the casing, allowing the valve to respond to conditions in the room.

 

  •  
Kit 3 - Full 2

Kit 3

Aero remote sensor with RA-N valve 

Combines a Danfoss Aero® thermostatic head with remote sensor, an RA-N DN15 angled valve body and RLV-S DN15 angled lockshield. The thermostat has a 7–26°C setting range, frost protection and provision for limiting or locking the temperature setting using limiter pins.

The head is fitted outside the cover or, at low level within the LST cover, with the separate sensor positioned outside and connected by a capillary tube extending up to 2 m. Suitable for two-pipe heating systems, the RA-N valve incorporates adjustable presetting to support hydraulic balancing.

The Aero® head uses a gas-filled thermostatic element for a faster response to temperature changes than conventional wax-filled heads.

 

 

  •  

Kit 4

Aero remote sensor with RA-DV valve 

Combines a Danfoss Aero® thermostatic head with remote sensor, an RA-DV DN15 angled Dynamic Valve™ and RLV-S DN15 angled lockshield. The thermostat has a 7–26°C setting range, frost protection and provision for limiting or locking the temperature setting using limiter pins.

The head is fitted inside the LST cover, with the separate sensor positioned outside and connected by a capillary tube extending up to 2 m. Designed for two-pipe heating systems, the RA-DV incorporates differential pressure regulation and automatic hydraulic balancing, maintaining a selected maximum flow limit of 10–135 litres per hour as system pressure changes within its operating range.

The Aero® head uses a gas-filled thermostatic element for a faster response to temperature changes than conventional wax-filled heads.

Kit 4 - Full 2

 Standard TRV Kits 

 For areas where temperature settings are managed by staff and occupant adjustment is not required. The thermostatic head and built-in sensor are enclosed within the LST cover, reducing access to the controls and exposure to accidental damage. The head fits directly to the valve, with no separate remote sensor or capillary tube. 

 

  •  
Kit 5 - Full 2

Kit 5

Aero RA built-in sensor with RA-N valve 

Combines a Danfoss Aero® RA thermostatic head with built-in sensor, an RA-N DN15 angled valve body and RLV-S DN15 angled lockshield. The thermostat has a 7–28°C setting range, frost protection and provision for limiting or locking the temperature setting using limiter pins.

Fitted directly to the valve inside the LST cover, the head automatically regulates water flow in response to the surrounding air temperature. No separate sensor or capillary tube is required, although suitable positioning and airflow are important to minimise the influence of heat within the casing. Temperature adjustment remains inside the cover, while the RA-N valve provides adjustable presetting to support hydraulic balancing in two-pipe heating systems.

The Aero® head uses a gas-filled thermostatic element for a faster response to temperature changes than conventional wax-filled heads.

 

 

  •  

Kit 6

Aero RA built-in sensor with RA-DV valve

The dynamic balancing upgrade to Kit 5, combining the Danfoss Aero® RA head with built-in sensor, an RA-DV DN15 angled Dynamic Valve™ and RLV-S DN15 angled lockshield. The thermostat retains the 7–28°C setting range, frost protection and provision for limiting or locking the temperature setting using limiter pins.

The built-in sensor regulates heating in response to air temperature inside the LST cover, with suitable positioning and airflow remaining important. The RA-DV adds automatic hydraulic balancing for two-pipe heating systems, combining thermostatic control with built-in differential pressure regulation. Maximum flow is set at the valve between 10–135 litres per hour before fitting the head, with the regulator maintaining the selected flow limit as system pressure changes within its operating range.

The Aero® head uses a gas-filled thermostatic element for a faster response to temperature changes than conventional wax-filled heads.

  •  
Kit 6 - Full 3

 Standard TRV and Lockshield Packs

 For installations using 15 mm copper pipework, these packs combine a thermostatic head with built-in sensor, valve body and matching lockshield. Available with a conventional RA-N valve or an RA-DV Dynamic Valve™ for automatic hydraulic balancing in two-pipe heating systems.

Kit 7 - Full 2

Kit 7

RAS-C² Radiator Pack with RA-N valve 

 

Combines a Danfoss RAS-C2 thermostatic head with built-in sensor, an RA-FS angled valve body and matching RLV-D lockshield, with 15 mm compression connections for copper pipework. The thermostat provides an 8–28°C setting range, frost protection and a positive shut-off setting.

Designed for two-pipe heating systems, the RA-FS valve supports bi-directional flow and incorporates a flow-direction selector that can be adjusted without removing the valve. The built-in sensor automatically regulates radiator flow in response to the surrounding air temperature.

The RAS-C² head uses a liquid-filled thermostatic element that responds to surrounding air temperature to automatically regulate radiator flow.

 

  •  
  •  

Kit 8

RAS-C² Radiator Pack with RA-DV valve 

The dynamic balancing upgrade to Kit 7, combining a Danfoss RAS-C2 thermostatic head with built-in sensor, an angled RA-DV Dynamic Valve™ and RLV-D lockshield. Supplied with 15 mm compression connections for copper pipework, the head retains the 8–28°C setting range, frost protection and positive shut-off setting.

Designed for two-pipe heating systems, the RA-DV adds built-in differential pressure regulation and automatic hydraulic balancing. Maximum flow is selectable between 10–135 litres per hour, with the regulator maintaining the selected flow limit as system pressure changes within its operating range.

The RAS-C² head uses a liquid-filled thermostatic element that responds to surrounding air temperature to automatically regulate radiator flow.


 

  •  
  •  
Kit 8 - Full 2
Contour_Danfoss_All_Kits_V1_5
dynamic valve upgrade 2

Choosing an RA-DV kit adds automatic hydraulic balancing to your selected control arrangement. Each radiator’s maximum flow is set at the valve and can be recorded on the radiator schedule, while built-in pressure regulation maintains the selected flow limit as system pressure changes within its operating range.

For specifiers and estates teams, this supports more consistent heat distribution and reduces the need for manual rebalancing as operating conditions change. Dynamic options are available across all four kit groups, retaining your chosen temperature control arrangement.

 

 

Need Help Choosing Your Kit?

Getting the valve, sensor and cover to work as one specification is easier before the order than after it. Contact Contour's technical team to confirm the appropriate kit, connections, sensor arrangement and balancing requirements for your installation — and receive the matching Danfoss data sheets and installation guides for your project file.

 

discuss_your_requirements_button

  •  
Richard_Holland_Photo

Richard Holland National Sales Manager

Need Some Advice From One of Our Experts?

We're here to help. For more information, or to find out more about our services, including site surveys; or talk to us about our comprehensive product range, please contact us today. We’ll do our best to get back to you within one working day.

Robert_Bennett_Photo

Robert Bennett Project Surveyor

Need Some Advice From One of Our Experts?

We're here to help. For more information, or to find out more about our services, including site surveys; or talk to us about our comprehensive product range, please contact us today. We’ll do our best to get back to you within one working day.

Laura_Oliver_Photo

Laura Oliver Customer Service Manager

Need Some Advice From One of Our Experts?

We're here to help. For more information, or to find out more about our services, including site surveys; or talk to us about our comprehensive product range, please contact us today. We’ll do our best to get back to you within one working day.

Ready to take the next step?

Just fill out the form in as much detail as you can, and an expert will be in touch within 24 hours.